Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Mass Spectrom Adv Clin Lab ; 32: 41-46, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38419980

RESUMEN

Introduction: Monitoring the atypical antipsychotic drug clozapine is crucial to ensure patient safety. This article showcases a high-throughput analytical method for measuring clozapine and its primary metabolite norclozapine (N-desmethylclozapine) in serum using paper spray mass spectrometry (PS-MS). Objectives: This study aimed to assess the viability of a PS-MS method for the rapid measurement of clozapine and norclozapine in human serum samples as an alternative to liquid chromatography mass spectrometry (LC-MS). Methods: Serum samples were processed by protein precipitation followed by deposition of the supernatant containing labelled internal standards onto paper spray substrates mounted in cartridges. Analytes were then analyzed using a triple quadrupole mass spectrometer equipped with a commercial paper spray ionization source. The results obtained from the patient samples were compared to those from a validated LC-MS assay. Results: PS-MS calibrations for clozapine and norclozapine were linear (R2 > 0.99) over five days. Between-run precision was below 8 %, and within-run precision did not exceed 10 %. When compared to a validated LC-MS method, the mean bias for 39 patient samples was -9% for clozapine and -1% for norclozapine, with no outliers. Mass spectrometry ion ratio comparisons indicated no interference for patient samples above the lower limit of quantification. There was less than 7 % change in the measured concentrations of both analytes over five days for samples dried on paper substrates. Notably, virtually no maintenance of the MS source was required during this study. Conclusion: This study illustrates the potential of PS-MS for serum drug monitoring in the clinical laboratory.

2.
Dent Mater ; 19(3): 188-98, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12628430

RESUMEN

OBJECTIVES: The most common metals and alloys used in dentistry may be exposed to a process of corrosion in vivo that make them cytotoxic. The biocompatibility of dental alloys is primarily related to their corrosion behavior. The aim of this work was to evaluate the corrosion behavior and thus the biocompatibility of the uncoated and coated stainless steels and compare the effect of type of coatings on corrosion behavior. METHODS: Three types of coatings, hydroxyapatite (HA), titanium (Ti), and a double-layer HA/Ti on AISI 316L stainless steel were made. HA coating was produced using plasma-spraying technique and Ti coating was made using physical vapor deposition process. In order to perform a novel double-layer composite coating, a top layer of HA was plasma-sprayed over a physical vapor deposited Ti layer on AISI 316L stainless steel. Structural characterization techniques including XRD, SEM and EDX were used to investigate the microstructure, morphology and crystallinity of the coatings. Electrochemical potentiodynamic tests were performed in physiological solutions in order to determine and compare the corrosion behavior of the coated and uncoated specimens as an indication of biocompatibility. RESULTS: Double-layer HA/Ti coating on AISI 316L SS had a positive effect on improvement of corrosion behavior. The decrease in corrosion current densities was significant for these coated specimens and was much lower than the values obtained for uncoated and single HA coated specimens. Ti coating on AISI 316L SS also has a beneficial effect on corrosion behavior. The results were compared with the results of corrosion behavior of HA coated commercially pure titanium (cpTi) and uncoated cpTi. SIGNIFICANCE: These results demonstrated that the double-layer HA/Ti coated 316L SS can be used as an endodontic implant and two goals including improvement of corrosion resistance and bone osteointegration can be obtained simultaneously.


Asunto(s)
Materiales Biocompatibles/química , Cerámica/química , Materiales Biocompatibles Revestidos/química , Aleaciones Dentales/química , Implantes Dentales , Acero Inoxidable/química , Corrosión , Cristalografía , Durapatita/química , Electroquímica , Microanálisis por Sonda Electrónica , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Titanio/química , Difracción de Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...